Manual Air Conditioner
CLIMATE CONTROL UNIT INSPECTION [MANUAL AIR CONDITIONER]
1. Remove the climate control unit. Manual Air Conditioner
2. Connect the climate control unit connector.
3. Connect the negative (-) lead of the tester to body ground.
4. Switch the ignition to ON.
5. By inserting the positive (+) lead of the tester into each climate control unit terminal, measure the voltage according to the terminal voltage table.
- If there is any malfunction, inspect the parts under "Inspection item (s)".
- If the parts under "Inspection item (s)" are found to be normal, replace the climate control unit.
Terminal Voltage Table (Reference)