Knock Sensor: Testing and Inspection
KNOCK SENSOR (KS) INSPECTION [LF]
NOTE:
- Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. Description and Operation
Resistance Inspection
1. Remove the battery cover.
2. Remove the negative battery cable. Removal and Replacement
3. Disconnect the KS connector.
4. Measure resistance between KS terminals A and B.
- If not within the specification, replace the KS. Service and Repair
- If the monitor item status/specification (reference) is not within the specification, even though the KS resistance is within the specification, perform the "Circuit Open/Short Inspection".
KS resistance
- Approx. 4.87 megohms
Circuit Open/Short Inspection
1. Disconnect the PCM connector.
2. Inspect the following wiring harnesses for an open or short circuit. (Continuity inspection)
Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
- KS terminal A and PCM terminal 2U
- KS terminal B and PCM terminal 2V
Short circuit
- If there is continuity, there is a short circuit. Repair or replace the wiring harness.
- KS terminal A and power supply
- KS terminal A and body ground
- KS terminal B and power supply
- KS terminal B and body ground