GF80.50-P-4005GH Acoustic Alarm, Function
GF80.50-P-4005GH Acoustic Alarm, Function
- with CODE (551a) Anti-theft alarm system (ATA)
The all-activity module (AAM) (N10) operates relay F1k2 to activate the acoustic alarm. The relay links the alarm signal horn (H3) to circuit 30. The signal provided is not a continuous signal but alternately a signal for one second and an interval for one second. If the acoustic alarm is not terminated beforehand, it stops after about 30 seconds.
If the acoustic alarm is activated by the panic switch at the remote control key, the two-tone signal system (H1) is actuated through the relay F1k2 in place of the alarm signal horn (H3). The duration and sequence of the alarm are as described above.
The alarm can be terminated by the activating ATA or deactivating ATA functions.