GF83.70-P-4000-03A Design of Burner Housing
GF83.70-P-4000-03A Design Of Burner Housing
MODEL 210
- with CODE (228) Stationary heater
MODEL 210 up to 31.8.96
- with ENGINE 602.982 with heater booster
MODEL 463 as of 1.6.94
- with CODE (H12) Stationary heater Webasto Tele Thermo Top S
In burner housing,
- burner pipe (2),
- burner with burner insert (1),
- glow pin (A6r2)
and
- flame monitor (A6r3)
are combined as one unit.
Coolant supply (4) and coolant outlet (3) are located on burner housing.
Illustration shows burner housing of stationary heater unit with coolant circulating pump (A6m1) connected. On heater booster heater unit without circulating pump, pump installation opening on burner housing is sealed tight with a sealing plug.
With stationary heater unit, version of burner insert depends on fuel.
Differentiating feature:
- Burner insert for petrol (5) with perforated plate
- Burner insert for diesel (6) with non-woven material
Heater booster heater unit is designed, in principle, for diesel operation.