GF07.61-P-3016BK ME-SFI Part Load/Full Load Operation - Function
GF07.61-P-3016BK ME-SFI Part Load/Full Load Operation - Function
The particular quantity of fuel is metered to the engine in line with the performance map. The fuel quantity depends on:
- Coolant temperature
- Intake air temperature (only in warming-up phase)
- Engine speed
- Engine load
- Closed-loop mixture control
- Intake manifold length
- Ignition angle.
Part load operation: When the engine is at operating temperature optimal emission levels and good fuel consumption are assured in combination with the lambda control.
Full load operation: Maximum engine torque is produced at a pedal value of > 90%. The injection time is extended accordingly for this purpose.