Operation CHARM: Car repair manuals for everyone.

GF54.21-P-6040GZE Upper Control Panel Control Module Component Description



GF54.21-P-6040GZE Upper Control Panel Control Module Component Description
- with CODE (489) Airmatic (air suspension with level adjustment and adaptive damping system ADS)
- with CODE (430) Offroad package
- except CODE (494) USA version







Location
The upper control panel control unit is located in the center console.

Task

Scanning the following switches:
- ESP OFF switch (N72/1s1)
- PTS OFF switch (N72/1s8)
- Left front HS [SIH] switch (N72/1s10)
- Right front HS [SIH] switch (N72/1s11)
- Left front seat ventilation switch (N72/1s13)
- Right front seat ventilation switch (N72/1s14)
- Comfort/Sport switch (ADS) (N72/1s31)
- Transmission mode switch (N72/1s32)
- Hazard warning system switch (N72/1s5)
- Stationary heater switch (N72/1s30)

Reading in the following function indicator lamps:
- Automatic child seat recognition airbag OFF indicator lamp (N72/1e1)
- ATA [EDW] function indicator (N72/1e2)

Voltage supply and reading in of data:
- of rotary light switch (S1) over an LIN bus
- of lower control panel control unit (N72) over an LIN bus

Function

ESP OFF switch
The ESP Off switch can be used to switch the anti-slip control of the "Electronic Stability Program" on and off. The function requirements for this switch is circuit 15 "ON". The function of the ESP systems is indicated in the instrument cluster (A1).

PTS OFF switch
The Parktronic system is activated or deactivated via the PTS OFF switch. If the switch is actuated, the upper control panel control unit sends a signal to the PTS control unit (N62) via CAN-B. The PTS control unit then sends a message requesting actuation of the status LED in the PTS OFF switch back to the upper control panel control unit.

Left front HS [SIH] switch and right front HS [SIH] switch The heated seats have 3 stages. One-time actuation of the SIH switch activates stage 3 of the heated seats (all 3 red LEDs light up). Further actuations switch to stage 2 (the two lower LEDs go on), to stage 1 (the lowest LED goes on), or the heated seats are switched off (no function indicator). The function requirements for this switch is circuit 15R "ON". Each press of the left front HS [SIH] switch and right front HS [SIH] switch is sent by the upper control panel control unit over the CAN-B.

Left front seat ventilation switch and right front seat ventilation switch (only model 164.8)

When the left front and right front seat ventilation switch is actuated, the upper control panel control unit sends a signal to the HS [SIH], seat ventilation and steering wheel heater control unit (N25/7) via CAN-B. The switch is used to switch the seat ventilation in the respective seat on and off, and also to control the ventilation output.

The level of ventilation output is displayed by indicator lamps in the respective switch.

Comfort/Sport switch (ADS)
The driver can program the damping level as desired using the Comfort/ Sport switch (ADS):
1. "AUTO" Skyhook mode
2. "SPORT" Firm damping
3. "COMFORT" Soft damping

In the "SPORT" setting the upper LED goes on and for the "COMFORT" setting the lower LED goes on. If the vehicle is in the "AUTO" mode nothing is displayed in the Comfort/Sport switch (ADS).

Transmission mode switch
By operating the transmission mode switch the driver can choose between a sporty (S) and manual (M) transmission mode. The transmission mode switch is read in by the upper control panel control unit and sent to the CAN-B. The central gateway control unit (N93) reads in this message and then sends it over the CAN-C to the fully integrated transmission control (VGS) control unit (Y3/8n4). Each respective transmission program is selected in the fully integrated transmission control (VGS) control unit.

The function requirements for this switch is circuit 15R "ON".

Hazard warning system switch
Pressing the hazard warning system switch wakes-up the upper control panel control unit from its "Sleep mode" and the hazard warning system function is activated. The message is sent cyclically (every 100 ms) until the function is deactivated by pressing the hazard warning system switch again. The flashing function illumination of the hazard warning system switch is triggered by the CAN message of the rear SAM control unit (N10/8). There is no faster flashing of a defective indicator lamp for the hazard warning flasher system. As soon as the hazard warning flasher function is activated the switch and controls illumination for the hazard warning system switch is switched off. The function illumination of the hazard warning system is not dimmed.

The selected function is confirmed when the indicator lamps (LEDs) light up. The pulse to light up is sent by each respective control unit.

STH switch
The function of the STH switch depends on the current terminal status. Whenever the stationary heater is activated, the AAC [KLA] control and operating unit (N22) receives a query as to whether heating or ventilation is required. The currently active function is displayed by an indicator lamp in the STH switch as follows:
- Indicator lamp red: Heating mode
- Indicator lamp blue: Ventilation mode
- Indicator lamp yellow: Activation of stationary heater via timer

Function with terminal 15R OFF
If the switch is actuated, the system is switched on or off immediately. When switched on, the upper control panel control unit sends a signal to the heater booster control unit (N33/2). The latter then sends the command to switch on the stationary heater to the AAC [KLA] control and operating unit.

Since the AAC [KLA] control and operating unit needs time to decide whether heating or ventilation is required, the red indicator lamp is activated by the upper control panel control unit immediately after the switch is actuated.

The AAC [KLA] control and operating unit permanently switches the indicator lamp to the appropriate color depending on whether heating or ventilation is required.

Function with terminal 15R ON
If the switch is actuated for less than 2 s with the system switched off, the timer menu is shown in the multifunction display (A1p13) in the instrument cluster. The system will be activated if the switch is pressed for a longer time.

If the system is already activated, it is switched off again immediately without the timer menu being displayed.

Discrete inputs:
- Circuit 30
- Circuit 31
- CAN-B

Discrete outputs:
- Circuit 30
- Circuit 31
- LIN bus

Voltage limit: The operating voltage is between 12 and 14 V.