AR91.40-P-0611-02RT Ignition of Removed Emergency Tensioning Retractors
AR91.40-P-0611-02RT Ignition Of Removed Emergency Tensioning Retractors
Component Identification:
Using the deployment device
1. Plug the 2-pin plug connector (8) into the unit to be scrapped.
2. Dial the rotary switch (4) to position "1".
3. Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.
Keep a distance of 10 m for safety.