Hydraulic System: Service and Repair
AR42.50-P-0001-01GS Mount Pressure Gauge
- with CODE (979) Special protection version
1 Switch off ignition.
2 Reduce pressure in booster circuit (press brake pedal approx. 30 times).
3 Remove angle piece (2) from hydraulic line (1).
4 Install adapter (3) and distributor (4) between angled fitting (2) and hydraulic line (1).
Pressure tester gotis://B_42/43.2_03.0
Instead of the adapter (2 external threads M10x1) a short brake line can also be bent to suit and then installed.
5 Connect test line (5) from pressure gauge to distributor (4).