Operation CHARM: Car repair manuals for everyone.

GF83.70-G-3038A Stationary Heater Malfunction Interlock Reset, Function




GF83.70-G-3038A Stationary Heater Malfunction Interlock Reset, Function
MODEL 463 as of 1.6.94 up to 31.5.12
- with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S

Function
Following a malfunction shut-off caused by a recognized malfunction, the heater goes to the malfunction interlock state. In this case it is necessary to reset the malfunction interlock after eliminating the cause of the malfunction. The stationary heater can be started again only in this manner.
^ Malfunction interlock reset
The malfunction interlock can be reset by switching off the heater and switching it back on again with the timer or the radio frequency remote control.
^ Malfunction interlock reset (as of 09/96)
The malfunction interlock can be reset with the hand-held tester (HHT) as of 09/96.
^ Malfunction interlock reset following malfunction switch- off due to overheating or electro-magnetic interference
In the event of a malfunction interlock caused by the heater overheating or by electro-magnetic interference, the malfunction interlock can be reset after eliminating the cause of the malfunction simply by interrupting the power supply.
This can be accomplished by momentarily removing and reinstalling fuse 20 (F1f20).