AR01.10-P-0010-01GS Connect Compression Recorder
AR01.10-P-0010-01GS Connect Compression Recorder
001 589 76 21 00
Compression tester
220 589 00 99 00
Electrical connection kit
1 Open cap (1) on jump-starting point (2) cover.
2 Clip connection terminal of compression recorder on terminal block terminal 30 (X4/30).
3 Remove cover (arrow) below right dashboard.
4 Remove starter relay (K6).
5 Connect up adapter line from electrical connection kit to slot (4).
6 Connect adapter cable to the cable of the compression recorder.