AR01.10-P-0010-01GV Connect Compression Tester
Connecting compression tester
1. Remove cover (1) of control module box.
2. Connect clamp (A) of compression tester to the terminal block (X12/3).
3. Separate connector of control module box (X35/63)
4. Connect adapter cable (2) with pin 6 of connector (X35/63).
5. Connect adapter cable (2) to the cable of the compression tester.