Check Caster and Assign to Tabular Value
AR40.20-P-0322-03CZ Check caster and assign to tabular value
Check and adjustment values for caster:
Axle level values:
Tolerance for caster ±30'
The level values are displayed by the electronic inclinometer in decimal degrees [°].
1 Obtain the caster value from the table taking into account the front axle (FA) level values and rear axle (RA) level values measured previously.
Example, see Table:
Front axle level value (FA): +7.0 degrees
Rear axle level value (RA): +3.5 degrees
= Caster value 9 degrees 44' ( ±30')