System Filled

NOTE: Determine oil pump (22) volume accuracy by sucking-in and forcing-out oil several times into measuring container several times before connecting to air conditioning system.

Oil Pump:





Refrigerant Oil Pump Application:





1. Put cold-flowing oil into measuring cup and draw-in with oil pump (22).
2. Remove closing cap from service valve (b) on hose line (14).
3. Connect oil hose (23) of oil pump (22) to service valve (b) and force oil quantity into system.