Test 4
TEST 4:Test 4:
Main Air Flaps - Open:
Test Conditions:
Selector Dial: MIN (engaged)
Function Button: "d"
Blower: "AUTOM"
Test Results/Observations:
- Monovalve closed.
- Recirculating pump not running.
- Compressor switched off.
- Main air flaps open (fresh air).
- Blower running (6.7 amps or 5th stage).