Diesel MFI Pump: Specifications
INJECTION TIMING SPECIFICATIONS:High Pressure or Flow Pressure Method:
Checking: 24 ±1° BTDC
Adjusting: 24° BTDC
Reference Impulse (RIV) Method:
Checking: 15 ±1° ATDC
Adjusting: 15° ATDC
TORQUE SPECIFICATIONS:
Closing plug to regulator (measuring point): 3O-35 Nm
Injection pump flange: 20-25 Nm
Injection line coupling nuts: 10-20 Nm
Pipe connection: 30-40 Nm