Operation CHARM: Car repair manuals for everyone.

Test 4

TEST 4:

Test 4:




Main Air Flaps - Open:




Test Conditions:
Selector Dial: MIN (engaged)
Function Button: "d"
Blower: "AUTOM"

Test Results/Observations:
- Monovalve closed.
- Recirculating pump not running.
- Compressor switched off.
- Main air flaps open (fresh air).
- Blower running (6.7 amps or 5th stage).