Testing Coding Plug
Testing coding plugRemove coding plug (R 29)
- production date (a),
- part number (b),
- jack designation (c).
Note: There is no jack designation A-G on some coding plugs. Check these coding plugs as shown on illustration.
Connect ohmmeter and check resistance values (refer to table), renew coding plug (R 29) if values are deviating.