Component Data
A/C TEMPERATUREMinimum at center outlet 41°F (5°C)
Maximum Compressor Cycling Temp. [1] 5°F (3°C)
HIGH PRESSURE SWITCH (RECEIVER DRIER)
Open Circuit Pressure 217±7.5 psi (15±0.5 bar)
Close Circuit Pressure 290±7.5 psi (20±0.5 bar)
2-FUNCTION PRESSURE SWITCH (RECEIVER DRIER)
LOW PRESSURE FUNCTION
Open Circuit Pressure =29±3 psi (2±0.2 bar)
Close Circuit Pressure >/=37±3 psi (2.6±0.2 bar)
HIGH PRESSURE FUNCTION
Open Circuit Pressure 435 psi (30 bar)
Close Circuit Pressure 319 psi (22 bar)
PRESSURE RELIEF VALVE
Opening Pressure 580±72 psi (40±5 bar)
Closing Pressure 72 psi (5 bar) less than Opening Psi
_____________________
[1] The temperature difference between the cut-out and cut-in of the A/C compressor.