AR54.10-P-0001Z Initial Filling of Battery
AR54.10-P-0001Z Initial Filling of Battery
Maximum Battery Fluid Level:
DANGER:
Explosion hazard from explosive gas.
Danger of poisoning and acid burns when battery acid is swallowed.
Danger of acid burns to skin and eyes from battery acid or when handling damaged lead-acid batteries.
- Fire, sparks, naked flame and smoking prohibited.
- Wear safety gloves, safety clothing and safety glasses which protect against acid.
- Only pour battery acid into suitable, appropriately marked containers.
1 Pour in battery electrolyte up to inner level marking with a filling device Leave battery to stand for about 20 minutes, then check electrolyte level and adjust to correct level, if necessary
Refer to Commercially Available Tools below