Checking Pneumatic Line For Leaks
Preliminary operation:
Check pneumatic function of the actuator, Testing and Inspection
Data
Special tool
Parts for the test Part no.
Sealing cap 000 987 11 45
Connecting piece (b) 007 997 61 82
Preparing test
1 When checking for leaks on individual lines, connect one end of the line to the tester and seal the other end with a sealing cap 000 987 11 45.
Test
Repair Information
In the event of leaks at the ends of the line, replace the connector plug or connector bush by a suitable adapter piece with a 50 mm long rubber connector.
Eliminate leaks of line with rubber connector.