Diesel MFI Pump: Specifications
INJECTION TIMING SPECIFICATIONS:Reference Impulse Method:
Checking: 14 +0.5° ATDC
Adjusting: 14 +0.5° ATDC
High or Low Pressure Flow Method:
Checking: 19° BTDC
Adjusting: 19° BTDC
TORQUE SPECIFICATIONS:
Closing plug to regulator (measuring point): 3O-35Nm
Injection pump flange: 20-25Nm
Injection line coupling nuts: 10-20Nm
Pipe connection: 30-40Nm