Base Module (Compressor Cutout Control)
Base Module (N16/1) Data Link Connector (X11/4):
The Base Module (N16/1) disengages the A/C compressor clutch in cases of a compressor overload condition and resultant poly-v-belt slippage. The base module will record the disengagement as a malfunction and store this information in memory.