Preparation For Test
Preliminary work: Diagnosis - Diagnostic Trouble Code (DTC) Memory. DTCM - Diagnostic Trouble Code Memory
Preparation for Test:
1. Review wiring diagrams:
2. All fuses OK.
3. Battery voltage > 11 V.
4. Disconnect battery ground cable prior to connecting or disconnecting any electrical connector to any control module (to prevent the storing of erroneous diagnostic trouble codes).
5. Voltage supply to control modules and data lines OK.
NOTE: For test measuring purposes the CAN connection to the following control modules must be connected:
- PSE control module (A37)
- Signal pickup-and activation module (SAM) (N10/1)
Conventional Tools, Test Equipment
Multimeter Fluke models 23, 83, 85, 87, available through the MBNA Standard Equipment Program.