Function of Shift Pressure
FUNCTION- The level of shift pressure is determined by the shift pressure regulating solenoid valve (Y3/6Y2) and the shift pressure regulating valve.
THE SHIFT PRESSURE
^ Controls the pressure in the engaging actuator during the shift phase.
^ Together with modulator pressure determines the pressure reduction, controlled by the overlap regulating valve, at the disengaging actuator
^ Initializes 2nd gear in emergency running mode
Also Refer To:
- Shift Pressure Regulating Solenoid Valve. Shift Pressure Regulating Solenoid Valve
- Modulator Pressure. Function of Modulator Pressure
- Shift Pressure Regulating Valve. Shift Pressure Regulating Valve
- Overlap Regulating Valve. Overlap Regulating Valve