Separating/Disconnecting Electrical Connectors In Left Footwell
Separating/Disconnecting Electrical Connectors In Left Footwell
1 Unlock and disconnect electrical connectors (1) on rear of light module (N7-1).
2 Disconnect positive lead (2) from connector (X4).
3 Remove left side paneling in footwell and open wiring duct on rocker panel.
4 Disconnect wires (3) at connector (X12/5).
5 Separate connector (X25).
6 Disconnect electrical connector from stop lamp switch.
7 Return all disconnected and separated wires and wiring harnesses back to fuse and relay box.