Function of Closing Power Windows With Convenience Feature
Function prerequisites
- Voltage not too low or too high and
- circuit 15 off and
- circuit 15R off and
- circuit 15C off.
Function
Each door control module (N69/1) or (N69/2), (models 202/210 also N69/3 or N69/4) receives the request for closing the power window with the convenience feature via the CAN-bus and then actuates the power window motor The motor is actuated until the door control module recognizes that the window is completely closed by means of the position recognition feature. The window can be closed with the convenience feature even when the window has not been synchronized. If actuated with the remote control key or lock switch ((USA), (J))
Closing the window with the convenience feature is interrupted when
- the request on the CAN-bus is no longer received or
- the power window is locked up or