Dust Filter For Heating / Air Conditioning
MODEL 129
Left Side
Arrows Lip seals
Right Side
1 Hood
B10/5 Outside temperature sensor
Arrows Screws and clamps
Arrow Filter cartridge
Removal / Installation
1 Pull off lip seals (arrows)
2 Unscrew screws (arrows)
3 Unclip clips (arrows)
4 Pullout outside temperature sensor (B10/5)
5 Remove hood (1)
6 Remove filter cartridge (arrow)
Installation:
Insert new filter cartridge, observe installation position (marking) The dust filter should always be replaced, never cleaned
7 Clean filter housing and hood (1)
8 Reinstall in reverse order