Initial Inspection (Function Test [11])
Air Conditioning (A/C)
Models 208 as of MY 1998
Function Test [11]
1. Review 11, 12, 13, 14, 15, 21, 22, 31, 41
2. Check condition of fuses F1-20, F1-25, F1-26, F1-38,
3. Check in-car temperature sensor aspirator blower by placing a small of paper ( arrow ) approximately 1/2 square " over in-car temperature sensor B10/4) vent grille with ignition ON and with soft top closed (model 206,465 only). If there is suffient ventilation the paper will remain on the vent grille,if not check aspirator blower for voltage supply and function. The after-run time for the blower motor is greater than six seconds.
4. Run engine at closed throttle and operating temperature (approx.80C engine coolant temperature) during entire test (ensure that the gear selector lever is in "P" and that the parking brake is engaged).
5. Manually open the center and side air outlets.
. Ensure that the Recurculation button is not depressed.