Removal and Replacement
AR54.10-P-0005I Remove/Install Battery
Shown On Model 220:
Removal, installation
DANGER:
- Explosion hazard from explosive gas. Danger of poisoning and acid burns where battery add is swallowed. Danger of acid burns to skin and eyes from battery acid or when handling damaged lead-add batteries.
- Flames, sparks, open light and smoking prohibited. Wear add resistant gloves, clothing and goggles. Store battery acid only in suitable, appropriately marked containers.
1 Remove ignition key
2 Pivot trunk cover up
3 Unscrew screw (1) and remove holder
4 Connect quiescent current retention unit
5 Disconnect ground lead (3) from battery
6 Remove gas vent line (5) from battery (G1)
NOTE: Installation: Ensure that gas vent line is routed through the line passage to the outside
7 Remove positive pole cover (4) upward
8 Disconnect positive lead (2) from battery
9 Remove battery (G1)
10 Install in opposite order
NOTE: Connect positive lead (2) first, then ground lead (3)