AZ82.70-P-0005-03A Retrofit Hands-Free System Wiring Harness



AZ82.70-P-0005-03A Retrofit Hands-Free System Wiring Harness
- with CODE (273) Provision for D-network handy telephone
- with CODE (354) CTEL antenna (GSM 900 and 1800 MHz)


The QualyTalk hands-free system should not be operated with continuous positive circuit 30.
Circuit 15 for VDA preequipment must be used. Circuit 15 is connected to VDA connector on chamber 10.

1 Check connection plugs of the VDA connection line (5) from the QualyTalk installation kit.

Pin 10 should be connected and pin 11 free.
If this is the case the connection lead (5) can be installed.
If this is not the case reconnect the pins in the connector.







2 Remove locking bar (R) toward rear.
3 Push cap (K) to one side.
4 Using a pointed object, unlock the plug in chamber 11 and pull out.
5 Insert plug in chamber 10 and lock in position.
6 Push on cap (K) and attach locking bar (R) again.