AR01.10-P-0010-01TX Connect Up Compression Recorder



AR01.10-P-0010-01TX Connect up compression recorder

Special Tools:




Component Identification:





1 Remove cover (1) on left fuse and relay box in the engine compartment.

Installation: Check seal in cover (1); replace seal if necessary.

2 Unlock plug (2) on driver-side SAM control unit with fuse and relay module (N10/1) and detach.
3 Fold out cover (3a).

Shown on model 211

Component Identification:





4 Connect compression recorder (01) to connection (3) and connect up using the adapter line (11) from the electrical connection kit at socket "5" on the plug (2).