Operation CHARM: Car repair manuals for everyone.

GF72.29-P-4002PP Desynchronization of Power Windows, Function




GF72.29-P-4002PP Desynchronization Of Power Windows, Function


Desynchronization
A desynchronization is performed if:
- Left front door control module (N69/1)
- Right front door control module (N69/2)
- Left rear door control module (N69/3) and/or
- Right rear door control module (N69/4)
- a power supply of UB<6.5V for t >30 s is connected to circuit 30
- The position counter for the window obtains a value greater than the maximum window travel during manual or automatic lowering
- the window reaches a position counter reading during manual or automatic closing which extends beyond the negative zero point tolerance or beyond the stored zero point
- 1 of 2 Hall sensor signals is faulty for 12 rotations of the armature

Automatic raising is no longer possible after desynchronization.

Model 203.7 has no rear door control modules or power window motors.