Operation CHARM: Car repair manuals for everyone.

GF80.50-P-4006TA Optical Alarm, Function



GF80.50-P-4006TA Optical Alarm, Function
- with CODE (551a) Anti-theft alarm system (ATA)
- with CODE (491) USA version


Optical alarm
All optical signals are output by the vehicle lighting The alarm output is controlled by the rear SAM control module with fuse and relay module (N10/2). Type and duration of the alarm are stored as performance maps in the rear SAM control module with fuse and relay module (N10/2).
The ATA alarm requests have priority over all normal light requests.

Alarm output
The optical signals are output via:
^ Taillamp, parking lamp, left outer rear fog lamp (E3e2) (only on model 211.0),
^ Taillamp, parking lamp, right outer rear fog lamp (E4e2) only on model 211.0),
^ Taillamp, left inner rear fog lamp (E3e5) (only on model 211.0),
^ Taillamp, right inner rear fog lamp (E4e5) (only on model 211.0),
^ Stop lamp, taillamp and left parking lamp (E3e9) (only on model 211.2),
^ Stop lamp, taillamp and right parking lamp (E4e9) (only on model 211.2),
^ Left fog lamp (E5/1),
^ Right fog lamp (E5/2) and
^ Front dome lamp (N70e1.