GF27.19-P-5149G Starter Lockout Contact, Component Description
GF27.19-P-5149G Starter lockout contact, component description
- Transmission 722.6
Component Identification:
Location
The starter lockout contact is located in the electric control unit and is permanently connected to the conductor tracks.
Task
The starter lockout contact detects the selector valve position and gear selector switch positions "P" and "N".
Component Identification:
Function
The starter lockout contact is operated in gear selector switch positions "P" and "N". This moves the permanent magnet away from the reed contact. The dry-reed contact is opened. The ETC control unit (N15/3) receives an electrical signal. The circuit to the starter is closed in gear selector switch positions "P" and "N".