GF54.10-P-2005GD DC/AC Converter Function
GF54.10-P-2005GD DC/AC Converter Function
Function requirements, general
^ Circuit 15R ON
The status of circuit 15 is sent by the electronic ignition lock control unit (N73) to the interior CAN (CAN B).
DC/AC converter, general
Only small electrical devices that require a 115 V A/C voltage may be connected to the 115 V power outlet (X58/34). The rear SAM control unit with fuse and relay module (N10/2) actuates the DC/AC converter control unit (N24/3) function.
Connecting a 115 V consumer to the 115 V power outlet is recognized by the microswitch power outlet (X58/34s1). The rear SAM control unit supplies the microswitch power outlet with power.
If a consumer is connected to the 115 V power outlet, this voltage is switched through to the control input for the DC/AC converter control unit. The DC/AC converter control unit converts the DC voltage of the on-board electrical system into a 115 V AC voltage. An LED integrated into the 115 V socket indicates the availability of AC voltage.
The maximum available electrical continuous load is P = 150 W, for a short-term up to P = 300 W is permissible for t = 2 s.
If the interior temperature of the DC/AC converter control unit rises above a defined limit value or if the output load exceeds the overload threshold of P = 160 W for t = 2 s, the DC/AC converter control unit switches off.
A calculation method stored in the DC/AC converter control unit prevents the converter from constantly switching between on and off when it gets close to the respective limit value.