GF80.50-P-3014R Trigger Alarm With Panic Switch, Function
GF80.50-P-3014R Trigger Alarm With Panic Switch, Function
- with CODE (494) USA version
Component Identification:
Trigger panic alarm
When the "PANIC" transmit button is pressed for approx. 2 s it transmits a radio signal to the right antenna amplifier module. The signal is relayed to the EIS control unit via the overhead control panel control unit.Parallel to the radio signal, an infrared signal is transmitted to the IR receiver (precise aiming required). This signal is read in by the corresponding door control unit and transmitted to the EIS control unit via CAN B.
In both cases the EIS control unit checks the access authorization of the transmitter key. If the access authorization is valid, the EIS control unit transmits the request "Panic alarm" to the CAN B bus. The driver-side SAM control unit triggers a visual and acoustic alarm regardless of the ATA status.
The panic alarm has priority over the ATA alarm.
Terminate panic alarm
The panic alarm can only be interrupted by actuating again the "PANIC" button on the transmitter key. Actuating the "Open" or "Close" button has no effect on the panic alarm triggered.
Visual alarm
The visual signals are output via:
^ Taillamps, parking lamps, rear fog lamps
^ Front fog lamps
^ Overhead control panel control unit
All visual signals are output for approx. 180 s.
Acoustic alarm
The acoustic alarm is output by the alarm signal horn for approx. 185 s.