Cylinder Block Assembly: Service Precautions
AH01.40-P-1000-03A Information on application of sealant to bottom part of crankcase
Sealing agent flow
The line drawn in (F) identifies the sealing compound application.
Apply sealant only to the specified surfaces with a bead of 2.0 mm 0.5 mm. The sealant must be processed within 10 min. The silicone bead must not be spread. Only the approved silicon sealant must be used.