AR91.60-P-0611-05A Deployment of Airbag Units When No Deployment Device Is Present
Deployment Of Airbag Units When No Deployment Device Is Present
Application of shop-made ignition cables
1. Make up ignition cable of min. 10 m length with pressure switch.
2. Plug the 2-pin plug connector into the corresponding airbag unit.
3. Connect ignition cables to the battery.
4. Press both pressure switches simultaneously.
5. For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 2 through 4 after plugging the ignition cable into the second squib.
CAUTION: Keep a distance of 10 meters for safety.