GF27.19-P-5149ACW Starter Lockout Contact, Component Description
GF27.19-P-5149ACW Starter lockout contact, component description
- 722.618/640/646/695/699
Component Identification:
Location
The starter lockout contact is located in the automatic transmission electric controller unit and is permanently connected to the conductor tracks.
Task
The starter lock-out contact detects selector lever positions "P and N.
Component Identification:
Design
Function
The starter lock-out contact is actuated in selector lever positions "P and N. This moves the permanent magnet (47) away from the dry-reed contact (48). The dry-reed contact (48) is opened. The electronic transmission-control control unit (N15/3) receives an electrical signal. The circuit to the starter (M1) is closed in selector lever positions "P" and N.