GF27.60-P-3017ACS Control Valve Pressure, Function
GF27.60-P-3017ACS control valve pressure, function
- Transmission 722.649
Function requirements for control valve pressure, general
^ Circuit 87 ON
^ Circuit 61 (engine running)
Control valve pressure, general
The control valve pressure is regulated at the control valve pressure regulating valve, depending on the working pressure, up to a maximum pressure of 8 bar.
It supplies the modulating pressure control solenoid valve (Y3/6y1), the shift pressure control solenoid valve (Y3/6y2) and shift valve pressure regulating valve.