Procedures
AH01.40-P-1000-01AMG Notes on application of sealant to timing case cover
Component Identification:
The lines (1) identify the application of the sealant.
The sealing surface must be cleaned. The sealant must only be applied to the specified surface in the form of a bead and to a height and width of 1.5 mm (±0.5 mm).
The sealant must be applied within 10 min. The sealant bead must not be spread. Use only sealant listed in the Repair Products.