Emission Control Systems: Description and Operation
GF14.00-P-3000MMA Exhaust Treatment Function
ENGINE 278.9 in MODEL 207.3 /4, 212.0 /2, 218
ENGINE 157.9 in MODEL 212.0 /2, 218
Function requirements for exhaust treatment, general points
^ Circuit 87M ON (engine control ON)
^ Engine running
Exhaust treatment, general
The task of exhaust treatment is to reduce the exhaust emissions:
- Nitrogen oxides (NOx)
- Hydrocarbon (HC)
- Carbon monoxide (CO)
To do this, amongst other things, the firewall catalytic converter must be rapidly brought up to operating temperature in order to reduce the exhaust emissions for a cold start.
Function sequence for exhaust treatment
The following subsystems are involved in exhaust treatment:
^ Function sequence for firewall catalytic converter
^ Function sequence for transmission shift delay
^ Function sequence for monitoring the catalytic converter efficiency
Function sequence for firewall catalytic converter
The pollutant in the exhaust emitted by the engine are converted chemically by the near-engine mounted firewall catalytic converters (three-way catalytic converter) for Lambda =1 (converted).
Through oxidation, carbon monoxide is converted to carbon dioxide (CO2) and hydrocarbon to water (H2O) and carbon dioxide.
Through reduction the nitrogen oxides are converted into nitrogen (N2)+ carbon dioxide.
Additional function requirements for transmission shift delay
^ Coolant temperature at start < 35°C
^ Vehicle speed <40 km/h
Function sequence for transmission shift delay
Transmission shift delay brings the firewall catalytic converter up to operating temperature more quickly after engine start. The ME-SFI [ME] control unit controls the transmission shift delay according to the following sensor and signal:
- Coolant temperature sensor (B11/4) (model 207, 212), coolant temperature sensor (B11/4) (model 218)
- Electronic stability program control unit (N30/4) (except code (233) DISTRONIC PLUS) or Electronic stability program control unit Premium (N30/7) (with code (233) DISTRONIC PLUS), wheel speed via chassis CAN (CAN E)
Transmission shift delay is active for a maximum of 60 s and is entirely electronic.
The ME-SFI [ME] control unit makes the requests to the fully integrated transmission control controller unit (Y3/8) to move the shift characteristics via the drive train CAN (CAN C).
Partial load gear shifts (1-2-1, 2-3-2) thus take place at higher engine speeds or at higher vehicle speeds.
Additional function requirements for monitoring the catalytic converter efficiency
^ Firewall catalytic converters at operating temperature
^ Lambda control enabled
Function sequence for monitoring the catalytic converter efficiency
Hydrocarbon (HC) emissions must not exceed the limit specified by the legal requirements.
The tasks of monitoring a firewall catalytic converter is to obtain from the oxygen storage capacity of firewall catalytic converters a statement about its aging and thus about the HC conversion.
The ME-SFI [ME] control unit reads in the following sensors to monitor the catalytic converter efficiency:
- LH and RH oxygen sensors upstream of catalytic converter (G3/3, G3/4)
- LH and RH oxygen sensors downstream of catalytic converter (G3/5, G3/6)
- Crankshaft Hall sensor (B70), engine speed
The oxygen stored during the "lean operating phase" is then reduced totally or partially during the "rich operating phase". With aging, the oxygen storage capacity of firewall catalytic converter is reduced, and so therefore is HC conversion.
Changes in the oxygen content downstream of the firewall catalytic converters are almost completely dampened by the high oxygen storage capacity of the firewall catalytic converters.
Consequently, the signals from the oxygen sensors downstream of firewall catalytic converters have low amplitude and are virtually constant.
When firewall catalytic converters are at operating temperature and the lambda control is enabled, the signal amplitudes of the oxygen sensors upstream of the firewall catalytic converters are compared with those downstream.
If the firewall catalytic converters are no longer working effectively, the oxygen sensors signals upstream have the same amplitude as those downstream.
A number of measurements take place in the lower partial-load range in the specified engine rpm range. The results are compared with a characteristic map in the ME-SFI [ME] control unit.
If a fault is detected, the ME-SFI [ME] control unit actuates the engine diagnosis indicator lamp (A1e58) on the instrument cluster (A1) via the chassis CAN (CAN E).
Any faults detected are stored in the fault memory of the ME-SFI [ME] control unit. These can be read out and deleted with Xentry Diagnostics.