Operation CHARM: Car repair manuals for everyone.

Procedures



AR72.10-P-1800-06SXS Release Pressure In Pressure Reservoir For Hydraulic Power Window In Front Door
(Model 221.1 with CODE Z07 Top Protection with hydraulic windows)






When relieving the pressure in the pressure reservoir for the hydraulic power window on the front door, ensure that the transmitter key is removed from the EIS control unit.

1. Open front door and remove emergency operation handle (1) from door lining.

The emergency operation handle (1) serves for manual actuation of the hydraulic valves in the block valve (2) for lifting and lowering the crank window.

2. Attach emergency operation handle (1) to bottom valve actuation, pull upward and hold until crank window is fully lowered.
3. Attach emergency operation handle (1) to upper valve actuation, pull down and hold until crank window is fully rolled up.
4. Roll crank window up and down until it stops indicating that the pressure in the pressure reservoir is completely relieved.

Rolling the crank window up and down causes the hydraulic oil to flow out of hydraulic reservoir back into the power window hydraulic pump.