Engine/A/T Controls - Intermittent Low Or Reduced Power

Vehicle intermittently has no power or reduced power, engine switches to unit protection function (limp-home mode)

Topic number LI18.30-P-054921

Version 1

Design group 18.30 Oil cooling system

Date 10-31-2012

Validity 204.077/277/377 as of facelift (code 802)

Reason for change

Complaint:
Vehicle intermittently has no power or reduced power, engine switches to unit protection function (limp-home mode)

Cause:
Limits for unit protection function set out too conservatively

Remedy:
Perform software update of engine and transmission control unit.

The software can be obtained from the STAR TekInfo: STAR TekInfo/Star Diagnosis / Downloads - Model 204 AMG with M156 engine and transmission SRCD

The software will be eventually available with DAS/Xentry version 11/2012.

Note:
Please take into consideration that, even after the temperature threshold is adjusted, the unit protection function may still become active at high outside temperatures and/or in extreme operating conditions.

In cases of issues still existing under normal operating conditions contact the DTS through the PTSS module.