Oxygen Sensor: Service and Repair
***UPDATED BY TSB #93236, NOVEMBER 10, 1993Oxygen Sensor:
REMOVAL
1. Disconnect harness terminal.
2. Remove sensor with suitable socket or wrench.
INSTALLATION
1. Apply a thin coating of anti-seize compound to the threads.
NOTE: Do not contaminate sensing tip with compound.
2. Install sensor and torque it to 21 Nm (15-17 ft lb).
3. Apply a thin coating of dielectric compound to the connector.
4. Connect harness terminal.