C10 Short Between Control Module and Hydraulic Pump Relay
- Key OFF.- Connect the breakout box with adapter to the antilock brake control module connector. Leave the antilock brake control module disconnected.
- Disconnect the hydraulic antilock actuator assembly connector.
- Measure the resistance of the "W/GN" wire between the BOB Pin 34 and ground.
- Measure the resistance of the "BR" wire between the BOB Pin 28 and ground.
- Are the resistances greater than 10,000 ohms?
YES -- Replace the antilock brake control module.
NO -- Service the wire(s) in question between the antilock brake control module and the hydraulic antilock actuator assembly.