BPA4 - Check IAC Valve Resistance
^ Disconnect the IAC valve connector.
^ Measure the resistance between the IAC valve terminals.
^ Is the resistance between 10.0-10.1 ohms at 20°C (68°F)?
YES -- GO to BPA5. BPA5 - Check FIC Solenoid Function