Manifold Gauge Set Connection
WARNING: USE EXTREME CARE AND OBSERVE ALL SAFETY PRECAUTIONS RELATED TO THE USE OF REFRIGERANTS.SPECIAL TOOLS
Description Tool Number
Rotunda R-134a High Side Quick Disconnect 176-R0037
Rotunda R-134a Low Side Quick Disconnect 176-R0036
R-134a Manifold Gauge Set 176-0032A
A/C MANIFOLD GAUGE SET CONNECTION
NOTE:
- Hoses should have shut-off devices or check valves within 305 mm (12 in) of the hose end to minimize the introduction of non-condensable gases (air) into the recovery station, as well as to minimize the amount of refrigerant released when the hoses are disconnected.
- Follow the equipment manufacturers procedures and instructions.
1. Turn both valves on R-134a Manifold Gauge Set all the way to the left to close the low-and-high-pressure hoses to the center manifold and center hose.
2. Remove the A/C charging valve caps from the low- and high-pressure gauge port valves.
3. Connect R-134a Manifold Gauge Set low-pressure hose and R-134a Low Side Quick Disconnect to the low-pressure gauge port valve.
4. Connect R-134a Manifold Gauge Set high-pressure hose and R-134a High Side Quick Disconnect to the high-pressure port valve.
5. Connect the center hose to the vacuum pump or the R-134a tank.