Fill Procedure
1. WARNING: Do not mix oil types, any mixture or any unapproved oil could lead to seal deterioration and leaks. A leak could ultimately cause loss of fluid, which could result in a loss of power steering assist.
Fill the reservoir.
^ Use Motorcraft MERCON(R) Multi-Purpose ATF XT-2-QDX or equivalent meeting Ford Specification MERCON(R).
2. Remove the ignition coil fuse to disable the vehicle.
3. Raise the front wheels off the floor.
4. CAUTION: Do not crank the engine for more than 15 seconds at a time. Allow the starter to cool for 1 minute before cranking again. Premature starter failure can occur.
CAUTION: Do not hold the steering wheel against the stops for more than three to five seconds at a time. Damage to the power steering pump could occur.
Turn the steering wheel from stop-to-stop while cranking the engine.
5. Lower the vehicle.
6. CAUTION: Do not overfill the reservoir.
Fill the reservoir.
^ Use Motorcraft MERCON(R) Multi-Purpose ATF XT-2-QDX or equivalent meeting Ford Specification MERCON(R).
7. Install the ignition coil fuse.