Fill Procedure
1. Check the power steering fluid level. If necessary, fill the reservoir to the correct level.^ Use Motorcraft MERCON Multi-Purpose ATF XT-2-QDX or MERCON equivalent.
WARNING: Do not mix oil types, any mixture or any unapproved oil can lead to seal deterioration and leaks. A leak can ultimately cause loss of fluid, which can result in a loss of power steering assist.
CAUTION: Do not overfill the reservoir.
2. Remove the fuel pump relay from the engine compartment fuse/relay panel.
3. Raise the front wheels off the floor.
4. Turn the steering wheel from stop-to-stop while cranking the engine.
CAUTION: Do not crank the engine for more than 15 seconds at a time. Allow the starter to cool for 1 minute before cranking again. Premature starter failure can occur.
CAUTION: Do not hold the steering wheel against the stops for more than three to five seconds at a time. Damage to the power steering pump can occur.
5. Lower the vehicle.
6. Check the power steering fluid level. If necessary, fill the reservoir to the correct level.
^ Use Motorcraft MERCON Multi-Purpose ATF XT-2-QDX or MERCON equivalent.
CAUTION: Do not overfill the reservoir.
7. Install the fuel pump relay in the engine compartment fuse/relay panel.